High pressure ducted unitsEBH
HIGH PRESSURE DUCTED UNIT, FOR HEATING AND COOLING,2 AND 4 PIPES, CAPACITY FROM 2,75 kW TO 31,05 kW. EBH high pressure ducted units, thanks to their high pressure fan decks, permit to satisfy every request of heating and cooling applications in big environments, where ducted air distribution is requested. They are suitable for horizontal installation. These are units for COOLING and HEATING applications; they are fed with cold and hot water and used according to their relevant performance features. EBH units are components of cooling and/or heating systems, designed for temperatures up to 75 °C. The EBH high pressure ducted units are also available for District Cooling applications: the water coils are designed with a reduced number of circuits, suitable for functioning with high water temperature difference. FEATURES: • 6 SIZES for horizontal ducted installation, 2 and 4 pipe system. • HIGH PRESSURE: they are designed for ducted installation with external static pressure up to 300 Pa. • STRUCTURE is realized in galvanized metal sheet, insulated internally; in order to facilitate all maintenance operations, the structure is divided in three separate and independent sections (condensate tray, fan deck, air filter). • HEAT EXCHANGERS can have 2, 3 or 4 rows, made by copper pipes and aluminium fin pack; 5-row coils are available for sizes 060 and 070. Up to size 050 all coils are provided with air vent valves. For sizes 060 and 070, the air vent valve is supplied only with the valve kit (optional). • REVERSIBLE WATER CONNECTIONS: these high-pressure units can be ordered with right (standard) or left water connections; it is possible to reverse the water connections on site, if necessary. • FAN DECK is composed by a 3 speed motor and two centrifugal galvanized steel scrolls. All motors are provided with a permanently connected capacitor and thermal protection of the windings with automatic reset. • CONDENSATE TRAY is realized in galvanized steel with water discharge pipes on both sides. • AIR FILTER consists of a washable polyester acrylic fibre, pleated and protected by a metal frame. The filter section can be easily removed for cleaning and maintenance. Filtration class G3. • ELECTRIC PANEL is composed by a terminal board with screw terminals contained in an ABS plastic box (IP30). A supporting relay is supplied as standard starting from size 040. • 4 BRACKETS are supplied along with the unit, to fix it to the ceiling.

- BA2/BA3 EBHAdditional 2 or 3 row coilsfind out more
- KRELElectric heaterfind out more
- EBH VALVEValve kit EBHfind out more
- KPC EBH/EDSCondensate pumpfind out more
- KPM/PA EBHAir delivery plenumfind out more
- FILTER F5Special filterfind out more
- EXTRA RALSpecial paintingfind out more

Additional coils for hot water with 2 or 3 rows, for units to be installed in 4 pipe systems (not available for EDS model).

Valve kit 3-way 4-port regulating valves, with either ON/OFF or modulating actuators, for 2- and 4-pipe systems, provided with copper connection kit.

The air delivery plenum is made of galvanized steel sheet, provided with spigots for the connection to the air ducts and with fixing supports.
It must be installed on the air outlet of the unit.
On the sides of the plenum there are pre-arranged holes that can be used when frontal spigots must be moved to side position. it is not available for EDS model.
- ORx10OPower card with Modbus for asynchronous motorsfind out more
- ORBx10OPower card with Modbus for brushless motorsfind out more
- ORC336/ORC346Round Analog console for wall installation.find out more
- ORC636/ORC646Round Cabin console for wall installation.find out more
- ORC236/ORC246Round Display console for wall installationfind out more
- ORC436/ORC446Round Touch console for wall installation.find out more
- ORS736/ORS746Round Manager supervisor for small systems (up to 16 units) on wall installation.find out more
- ORS810Round Master supervisor for intermediate systems (up to 100 units)find out more
- ORS940Round Net, an embedded system complete with web server, which allows the management of plants up to 250 unitsfind out more
- Oxx50Multitask additional cardfind out more
- Round Clima (app)Mobile applicationfind out more

Additional coils for hot water with 2 or 3 rows, for units to be installed in 4 pipe systems (not available for EDS model).

Valve kit 3-way 4-port regulating valves, with either ON/OFF or modulating actuators, for 2- and 4-pipe systems, provided with copper connection kit.

The air delivery plenum is made of galvanized steel sheet, provided with spigots for the connection to the air ducts and with fixing supports.
It must be installed on the air outlet of the unit.
On the sides of the plenum there are pre-arranged holes that can be used when frontal spigots must be moved to side position. it is not available for EDS model.

Electronic card mounted on the unit, it is designed to fully regulate (directly or via Modbus) the water terminal units. The card is able to control: MANAGEMENT OF OUTPUTS/INPUTS: • ON/OFF 230V VALVES: 2 outputs (230V) for controlling the hot water valve and the cold water valve. • MODULATING VALVES: 2 analog 0-10V Outputs for controlling the hot water valve and the cold water valve. • FAN: 3 outputs (230V) for 3-speed control (Min-Med-Max). • ELECTRIC HEATER: 230V command signal for electrical resistance control. • ROOM TEMPERATURE: Analog input for the connection of a room temperature sensor. • WATER TEMPERATURE: Analog input for the connection of a water temperature probe • DELIVERY AIR TEMPERATURE: Analog input for the connection of a supply air temperature probe • WINDOW CONTACT: Configurable digital input for managing the window opening contact • MULTIFUNCTION INPUT: Configurable input for the management of differential pressure switch, STAND-BY forcing, Season changeover, AC motor alarm, Forcing ventilation, Economy, External temperature sensor. • PUMP/DIFFERENTIAL PRESSURE SWITCH ALARM: Configurable input for managing the condensate pump alarm or differential pressure switch alarm. COMMUNICATION PORTS: • MODBUS LOCAL BUS: 485 communication port with Modbus protocol for the MASTER / SLAVE connection of the units. • MODBUS CONSOLE BUS: 485 communication port with Modbus protocol for connecting the LOCAL Console. • MODBUS BMS BUS: 485 communication port with Modbus protocol for the connection of the BMS supervisor. INTERCONNECTION OF ADDITIONAL MULTIFUNCTION CARD: • CONNECTION FOR MULTITASK CARD: The multitask expansion card makes available through relays the contacts for controlling the 24V ON/OFF valves, alarm contact, fan contact or card status.

Electronic card mounted on the unit, it is designed to fully regulate (directly or via Modbus) the water terminal units. The card is able to control: MANAGEMENT OF OUTPUTS/INPUTS: • ON/OFF 230V VALVES: 2 outputs (230V) for controlling the hot water valve and the cold water valve. • MODULATING VALVES: 2 analog 0-10V Outputs for controlling the hot water valve and the cold water valve. • BRUSHLESS FAN: 0/10V analog output for controlling the brushless motor and relative input for managing any alarms. • ELECTRIC HEATER: 230V command signal for electrical resistance control. • ROOM TEMPERATURE: Analog input for the connection of a room temperature sensor. • WATER TEMPERATURE: Analog input for the connection of a water temperature probe • DELIVERY AIR TEMPERATURE: Analog input for the connection of a supply air temperature probe • WINDOW CONTACT: Configurable digital input for managing the window opening contact • MULTIFUNCTION INPUT: Configurable input for the management of differential pressure switch, STAND-BY forcing, Season changeover, AC motor alarm, Forcing ventilation, Economy, External temperature sensor. • PUMP/DIFFERENTIAL PRESSURE SWITCH ALARM: Configurable input for managing the condensate pump alarm or differential pressure switch alarm. COMMUNICATION PORTS: • MODBUS LOCAL BUS: 485 communication port with Modbus protocol for the MASTER / SLAVE connection of the units. • MODBUS CONSOLE BUS: 485 communication port with Modbus protocol for connecting the LOCAL Console. • MODBUS BMS BUS: 485 communication port with Modbus protocol for the connection of the BMS supervisor. INTERCONNECTION OF ADDITIONAL MULTIFUNCTION CARD: • CONNECTION FOR MULTITASK CARD: The multitask expansion card makes available through relays the contacts for controlling the 24V ON/OFF valves, alarm contact, fan contact or card status.

Round Analog console for wall installation. Available in white (ORC336) or black (ORC346). Functions: - On / Off status setting - Room temperature setting - Selection of the fan speed - Manual Summer / Winter changeover Also available for wall built-in "503" module (white ORC335 or black ORC345).

Round Cabin console for wall installation. Functions: - On / Off status setting - Room temperature setting - Selection of the ventilation speed and manual Summer / Winter switching are managed by the central system Also available for wall built-in "503" module (white ORC635 or black ORC645).

Round Display console for wall installation Available in white (ORC236) or black (ORC246). Functions and features: - Off / Economy / Comfort status - room temperature setting - operating mode setting (cooling-heating-ventilation) - fan speed selection - alarms and warnings - backlit display Also available for wall built-in "503" module (white ORC235 or black ORC245).

Round Touch console for wall installation. Available in white (ORC436) or black (ORC446). Functions and features: - Off / Economy / Comfort status - room temperature setting - operating mode setting (cooling-heating-ventilation) - 4.3 inch screen and capacitive touch - weekly programming of all units connected to the same network. Also available for wall built-in "503" module (white ORC435 or black ORC445).

Round Manager supervisor for small systems (up to 16 units), on wall installation. Available in white (ORS736) or black (ORS746). Functions: - 4.3 inch screen and capacitive touch - Wi-Fi connectivity - connection to a cloud server - remote management via dedicated app - IOT friendly - weekly programming of all units connected to the same network. Also available for wall built-in "503" module (white ORS735 or black ORS736).

Round Master supervisor for intermediate systems (up to 100 units) Functions: - 7-inch screen and capacitive touch, - Wi-Fi connectivity - connection to a cloud server - remote management via dedicated app - IOT friendly - weekly programming of all units connected to the same network - allows interaction between different devices of the HVAC system: (cooling and heating units, HVAC system pumps, modulating valves for radiant systems, thermal zone valves, hydronic terminal units

Round Net, an embedded system complete with web server, which allows the management of plants up to 250 units. Functions: - Wi-Fi connectivity - connection to a cloud server - remote management via dedicated app - IOT friendly - weekly programming of all units connected to the same network - allows interaction between different devices of the HVAC system: (cooling and heating units, HVAC system pumps, modulating valves for radiant systems, thermal zone valves, hydronic terminal units

The Multitask Omnibus 360 card contains 5 relay (powered by OPower card), for the connection of: - 2 electro thermic valves, 24V~ with the same activation mode of VH and VC valves. - An auxiliary fan for air changing and/or free cooling - Contact for the external signal for one or more Warning status of the OPower card (warning for Air Sensor, Check Sensor, Fault Motor) - Contact to manage the external air damper.

Round Clima is the mobile application that permits to manage the supervision system by remote, via smartphone or tablet.
It is compatible with Android and iOS operating systems. It is available only in presence of one of the OSuper devices: Round Manager,
Round Master and Round Net (Round Clima Plus).
- EDCRRemote microprocessor for brushless motorfind out more
- ESTBrushless motor with inverter for fancoilsfind out more

Additional coils for hot water with 2 or 3 rows, for units to be installed in 4 pipe systems (not available for EDS model).

Valve kit 3-way 4-port regulating valves, with either ON/OFF or modulating actuators, for 2- and 4-pipe systems, provided with copper connection kit.

The air delivery plenum is made of galvanized steel sheet, provided with spigots for the connection to the air ducts and with fixing supports.
It must be installed on the air outlet of the unit.
On the sides of the plenum there are pre-arranged holes that can be used when frontal spigots must be moved to side position. it is not available for EDS model.

Electronic card mounted on the unit, it is designed to fully regulate (directly or via Modbus) the water terminal units. The card is able to control: MANAGEMENT OF OUTPUTS/INPUTS: • ON/OFF 230V VALVES: 2 outputs (230V) for controlling the hot water valve and the cold water valve. • MODULATING VALVES: 2 analog 0-10V Outputs for controlling the hot water valve and the cold water valve. • FAN: 3 outputs (230V) for 3-speed control (Min-Med-Max). • ELECTRIC HEATER: 230V command signal for electrical resistance control. • ROOM TEMPERATURE: Analog input for the connection of a room temperature sensor. • WATER TEMPERATURE: Analog input for the connection of a water temperature probe • DELIVERY AIR TEMPERATURE: Analog input for the connection of a supply air temperature probe • WINDOW CONTACT: Configurable digital input for managing the window opening contact • MULTIFUNCTION INPUT: Configurable input for the management of differential pressure switch, STAND-BY forcing, Season changeover, AC motor alarm, Forcing ventilation, Economy, External temperature sensor. • PUMP/DIFFERENTIAL PRESSURE SWITCH ALARM: Configurable input for managing the condensate pump alarm or differential pressure switch alarm. COMMUNICATION PORTS: • MODBUS LOCAL BUS: 485 communication port with Modbus protocol for the MASTER / SLAVE connection of the units. • MODBUS CONSOLE BUS: 485 communication port with Modbus protocol for connecting the LOCAL Console. • MODBUS BMS BUS: 485 communication port with Modbus protocol for the connection of the BMS supervisor. INTERCONNECTION OF ADDITIONAL MULTIFUNCTION CARD: • CONNECTION FOR MULTITASK CARD: The multitask expansion card makes available through relays the contacts for controlling the 24V ON/OFF valves, alarm contact, fan contact or card status.

Electronic card mounted on the unit, it is designed to fully regulate (directly or via Modbus) the water terminal units. The card is able to control: MANAGEMENT OF OUTPUTS/INPUTS: • ON/OFF 230V VALVES: 2 outputs (230V) for controlling the hot water valve and the cold water valve. • MODULATING VALVES: 2 analog 0-10V Outputs for controlling the hot water valve and the cold water valve. • BRUSHLESS FAN: 0/10V analog output for controlling the brushless motor and relative input for managing any alarms. • ELECTRIC HEATER: 230V command signal for electrical resistance control. • ROOM TEMPERATURE: Analog input for the connection of a room temperature sensor. • WATER TEMPERATURE: Analog input for the connection of a water temperature probe • DELIVERY AIR TEMPERATURE: Analog input for the connection of a supply air temperature probe • WINDOW CONTACT: Configurable digital input for managing the window opening contact • MULTIFUNCTION INPUT: Configurable input for the management of differential pressure switch, STAND-BY forcing, Season changeover, AC motor alarm, Forcing ventilation, Economy, External temperature sensor. • PUMP/DIFFERENTIAL PRESSURE SWITCH ALARM: Configurable input for managing the condensate pump alarm or differential pressure switch alarm. COMMUNICATION PORTS: • MODBUS LOCAL BUS: 485 communication port with Modbus protocol for the MASTER / SLAVE connection of the units. • MODBUS CONSOLE BUS: 485 communication port with Modbus protocol for connecting the LOCAL Console. • MODBUS BMS BUS: 485 communication port with Modbus protocol for the connection of the BMS supervisor. INTERCONNECTION OF ADDITIONAL MULTIFUNCTION CARD: • CONNECTION FOR MULTITASK CARD: The multitask expansion card makes available through relays the contacts for controlling the 24V ON/OFF valves, alarm contact, fan contact or card status.

Round Analog console for wall installation. Available in white (ORC336) or black (ORC346). Functions: - On / Off status setting - Room temperature setting - Selection of the fan speed - Manual Summer / Winter changeover Also available for wall built-in "503" module (white ORC335 or black ORC345).

Round Cabin console for wall installation. Functions: - On / Off status setting - Room temperature setting - Selection of the ventilation speed and manual Summer / Winter switching are managed by the central system Also available for wall built-in "503" module (white ORC635 or black ORC645).

Round Display console for wall installation Available in white (ORC236) or black (ORC246). Functions and features: - Off / Economy / Comfort status - room temperature setting - operating mode setting (cooling-heating-ventilation) - fan speed selection - alarms and warnings - backlit display Also available for wall built-in "503" module (white ORC235 or black ORC245).

Round Touch console for wall installation. Available in white (ORC436) or black (ORC446). Functions and features: - Off / Economy / Comfort status - room temperature setting - operating mode setting (cooling-heating-ventilation) - 4.3 inch screen and capacitive touch - weekly programming of all units connected to the same network. Also available for wall built-in "503" module (white ORC435 or black ORC445).

Round Manager supervisor for small systems (up to 16 units), on wall installation. Available in white (ORS736) or black (ORS746). Functions: - 4.3 inch screen and capacitive touch - Wi-Fi connectivity - connection to a cloud server - remote management via dedicated app - IOT friendly - weekly programming of all units connected to the same network. Also available for wall built-in "503" module (white ORS735 or black ORS736).

Round Master supervisor for intermediate systems (up to 100 units) Functions: - 7-inch screen and capacitive touch, - Wi-Fi connectivity - connection to a cloud server - remote management via dedicated app - IOT friendly - weekly programming of all units connected to the same network - allows interaction between different devices of the HVAC system: (cooling and heating units, HVAC system pumps, modulating valves for radiant systems, thermal zone valves, hydronic terminal units

Round Net, an embedded system complete with web server, which allows the management of plants up to 250 units. Functions: - Wi-Fi connectivity - connection to a cloud server - remote management via dedicated app - IOT friendly - weekly programming of all units connected to the same network - allows interaction between different devices of the HVAC system: (cooling and heating units, HVAC system pumps, modulating valves for radiant systems, thermal zone valves, hydronic terminal units

The Multitask Omnibus 360 card contains 5 relay (powered by OPower card), for the connection of: - 2 electro thermic valves, 24V~ with the same activation mode of VH and VC valves. - An auxiliary fan for air changing and/or free cooling - Contact for the external signal for one or more Warning status of the OPower card (warning for Air Sensor, Check Sensor, Fault Motor) - Contact to manage the external air damper.

Round Clima is the mobile application that permits to manage the supervision system by remote, via smartphone or tablet.
It is compatible with Android and iOS operating systems. It is available only in presence of one of the OSuper devices: Round Manager,
Round Master and Round Net (Round Clima Plus).

Microprocessor control, for "on wall" installation, designed for water terminal units equipped with Brushless motors (EST Inverter Technology): SV, SV/AF, PV, PV/AF, SVR.
It permits to control the type of ventilation (fan thermostated or fan continuously running) the fan speeds (0-10V or Auto), SUMMER/WINTER switch and room temperature thermostat.

The brushless electric motor is composed by a rotor having permanent magnets, whose magnetic fields interact with the ones producedby the stator winding.
The transfer of current isno longer by mechanical commutation (sliding contacts) but by an electronic commutation system: one electronic controller (inverter) powers the motor’s stator and generates rotating magnetic fields, that determine the rotor’s speed.
- CBL10Electric box CBL10find out more
- CBL20Master & Slave cardfind out more
- CBL30Electric box CBL30find out more
- CSROORemote control panel 3 speedsfind out more
- CMR00Room temperature thermostat, 3 speeds, S/W switchfind out more
- CER00Microprocessor control with thermostat, 3 speeds, Auto S/W switchfind out more
- CER10/BMicroprocessor control as CER00 for modulating valvesfind out more
- CER20Microprocessor control with thermostat, Auto speeds, Auto S/W switchfind out more
- CER30/BMicroprocessor control as CER20, for modulating valvesfind out more
- CER31Microprocessor control as CER30/B, power supply 24Vfind out more
- TAD10Room temperature thermostat, S/W switchfind out more
- WSWater sensorfind out more
- ASAir sensorfind out more

Additional coils for hot water with 2 or 3 rows, for units to be installed in 4 pipe systems (not available for EDS model).

Valve kit 3-way 4-port regulating valves, with either ON/OFF or modulating actuators, for 2- and 4-pipe systems, provided with copper connection kit.

The air delivery plenum is made of galvanized steel sheet, provided with spigots for the connection to the air ducts and with fixing supports.
It must be installed on the air outlet of the unit.
On the sides of the plenum there are pre-arranged holes that can be used when frontal spigots must be moved to side position. it is not available for EDS model.

Electronic card mounted on the unit, it is designed to fully regulate (directly or via Modbus) the water terminal units. The card is able to control: MANAGEMENT OF OUTPUTS/INPUTS: • ON/OFF 230V VALVES: 2 outputs (230V) for controlling the hot water valve and the cold water valve. • MODULATING VALVES: 2 analog 0-10V Outputs for controlling the hot water valve and the cold water valve. • FAN: 3 outputs (230V) for 3-speed control (Min-Med-Max). • ELECTRIC HEATER: 230V command signal for electrical resistance control. • ROOM TEMPERATURE: Analog input for the connection of a room temperature sensor. • WATER TEMPERATURE: Analog input for the connection of a water temperature probe • DELIVERY AIR TEMPERATURE: Analog input for the connection of a supply air temperature probe • WINDOW CONTACT: Configurable digital input for managing the window opening contact • MULTIFUNCTION INPUT: Configurable input for the management of differential pressure switch, STAND-BY forcing, Season changeover, AC motor alarm, Forcing ventilation, Economy, External temperature sensor. • PUMP/DIFFERENTIAL PRESSURE SWITCH ALARM: Configurable input for managing the condensate pump alarm or differential pressure switch alarm. COMMUNICATION PORTS: • MODBUS LOCAL BUS: 485 communication port with Modbus protocol for the MASTER / SLAVE connection of the units. • MODBUS CONSOLE BUS: 485 communication port with Modbus protocol for connecting the LOCAL Console. • MODBUS BMS BUS: 485 communication port with Modbus protocol for the connection of the BMS supervisor. INTERCONNECTION OF ADDITIONAL MULTIFUNCTION CARD: • CONNECTION FOR MULTITASK CARD: The multitask expansion card makes available through relays the contacts for controlling the 24V ON/OFF valves, alarm contact, fan contact or card status.

Electronic card mounted on the unit, it is designed to fully regulate (directly or via Modbus) the water terminal units. The card is able to control: MANAGEMENT OF OUTPUTS/INPUTS: • ON/OFF 230V VALVES: 2 outputs (230V) for controlling the hot water valve and the cold water valve. • MODULATING VALVES: 2 analog 0-10V Outputs for controlling the hot water valve and the cold water valve. • BRUSHLESS FAN: 0/10V analog output for controlling the brushless motor and relative input for managing any alarms. • ELECTRIC HEATER: 230V command signal for electrical resistance control. • ROOM TEMPERATURE: Analog input for the connection of a room temperature sensor. • WATER TEMPERATURE: Analog input for the connection of a water temperature probe • DELIVERY AIR TEMPERATURE: Analog input for the connection of a supply air temperature probe • WINDOW CONTACT: Configurable digital input for managing the window opening contact • MULTIFUNCTION INPUT: Configurable input for the management of differential pressure switch, STAND-BY forcing, Season changeover, AC motor alarm, Forcing ventilation, Economy, External temperature sensor. • PUMP/DIFFERENTIAL PRESSURE SWITCH ALARM: Configurable input for managing the condensate pump alarm or differential pressure switch alarm. COMMUNICATION PORTS: • MODBUS LOCAL BUS: 485 communication port with Modbus protocol for the MASTER / SLAVE connection of the units. • MODBUS CONSOLE BUS: 485 communication port with Modbus protocol for connecting the LOCAL Console. • MODBUS BMS BUS: 485 communication port with Modbus protocol for the connection of the BMS supervisor. INTERCONNECTION OF ADDITIONAL MULTIFUNCTION CARD: • CONNECTION FOR MULTITASK CARD: The multitask expansion card makes available through relays the contacts for controlling the 24V ON/OFF valves, alarm contact, fan contact or card status.

Round Analog console for wall installation. Available in white (ORC336) or black (ORC346). Functions: - On / Off status setting - Room temperature setting - Selection of the fan speed - Manual Summer / Winter changeover Also available for wall built-in "503" module (white ORC335 or black ORC345).

Round Cabin console for wall installation. Functions: - On / Off status setting - Room temperature setting - Selection of the ventilation speed and manual Summer / Winter switching are managed by the central system Also available for wall built-in "503" module (white ORC635 or black ORC645).

Round Display console for wall installation Available in white (ORC236) or black (ORC246). Functions and features: - Off / Economy / Comfort status - room temperature setting - operating mode setting (cooling-heating-ventilation) - fan speed selection - alarms and warnings - backlit display Also available for wall built-in "503" module (white ORC235 or black ORC245).

Round Touch console for wall installation. Available in white (ORC436) or black (ORC446). Functions and features: - Off / Economy / Comfort status - room temperature setting - operating mode setting (cooling-heating-ventilation) - 4.3 inch screen and capacitive touch - weekly programming of all units connected to the same network. Also available for wall built-in "503" module (white ORC435 or black ORC445).

Round Manager supervisor for small systems (up to 16 units), on wall installation. Available in white (ORS736) or black (ORS746). Functions: - 4.3 inch screen and capacitive touch - Wi-Fi connectivity - connection to a cloud server - remote management via dedicated app - IOT friendly - weekly programming of all units connected to the same network. Also available for wall built-in "503" module (white ORS735 or black ORS736).

Round Master supervisor for intermediate systems (up to 100 units) Functions: - 7-inch screen and capacitive touch, - Wi-Fi connectivity - connection to a cloud server - remote management via dedicated app - IOT friendly - weekly programming of all units connected to the same network - allows interaction between different devices of the HVAC system: (cooling and heating units, HVAC system pumps, modulating valves for radiant systems, thermal zone valves, hydronic terminal units

Round Net, an embedded system complete with web server, which allows the management of plants up to 250 units. Functions: - Wi-Fi connectivity - connection to a cloud server - remote management via dedicated app - IOT friendly - weekly programming of all units connected to the same network - allows interaction between different devices of the HVAC system: (cooling and heating units, HVAC system pumps, modulating valves for radiant systems, thermal zone valves, hydronic terminal units

The Multitask Omnibus 360 card contains 5 relay (powered by OPower card), for the connection of: - 2 electro thermic valves, 24V~ with the same activation mode of VH and VC valves. - An auxiliary fan for air changing and/or free cooling - Contact for the external signal for one or more Warning status of the OPower card (warning for Air Sensor, Check Sensor, Fault Motor) - Contact to manage the external air damper.

Round Clima is the mobile application that permits to manage the supervision system by remote, via smartphone or tablet.
It is compatible with Android and iOS operating systems. It is available only in presence of one of the OSuper devices: Round Manager,
Round Master and Round Net (Round Clima Plus).

Microprocessor control, for "on wall" installation, designed for water terminal units equipped with Brushless motors (EST Inverter Technology): SV, SV/AF, PV, PV/AF, SVR.
It permits to control the type of ventilation (fan thermostated or fan continuously running) the fan speeds (0-10V or Auto), SUMMER/WINTER switch and room temperature thermostat.

The brushless electric motor is composed by a rotor having permanent magnets, whose magnetic fields interact with the ones producedby the stator winding.
The transfer of current isno longer by mechanical commutation (sliding contacts) but by an electronic commutation system: one electronic controller (inverter) powers the motor’s stator and generates rotating magnetic fields, that determine the rotor’s speed.

Self-extinguishing plastic box (class V0), which contains a 12 pole terminal board and a voltage transformer (230/24 V~ 10VA), for the electrical connection of the modulating valves.
It is supplied as standard when the regulators CER10, CER30/B and CER31 are requested.

Self-extinguishing plastic box (class V0), which contains a 12 pole terminal board and a power relay card (230 V~): this card is requested either when an electric heater is mounted on the fancoil unit or to control the fan speeds in Master/Slave configuration. It can be combined with the following regulators: CMR00, CER00 and CER20

Self-extinguishing plastic box (class V0), which contains a 12 pole terminal board, a voltage transformer (230/24 V~ 10 VA) for the electrical connection of the modulating valves and/or 24V~ controls, a power relay card (24 V~), which is requested to control the fan speeds in Master/Slave configuration.
It can be combined with the following regulators: CER10, CER31, CER00 and CER20 (with power supply 24 V).

Remote controller, suitable only for the fan speed selection of a unit (fancoil, cassette, blower) installed in 2 pipe systems.
The controller is provided with terminals for the connection of the minimum water temperature thermostat (TM) and of a remote thermostat (mod. TAD10).
FEATURES
Fan speed selector (HIGH – OFF – MED – LOW)

The remote thermostat is suitable for the selection of the main functions of a unit (fancoil, cassette, blower): type of ventilation, fan speed selection, Summer/Winter switch and room temperature control.
The controller is provided with terminals for the connection of the minimum water temperature thermostat (TM) and of the cooling «EVC» and/or heating «EVH» on/off valves.
FEATURES
• Selector for the ventilation (THERMOSTATED – OFF – CONTINUOUSLY RUNNING)
• Fan speed selector (HIGH - MED - LOW)
• WINTER – 0 – SUMMER selector
• Room temperature knob (7÷30 °C). The «Comfort zone» is duly highlighted (about 20÷25 °C).
• Plastic pins for limiting the temperature range

Remote microprocessor control suitable for the complete control of a unit (fancoil, cassette, blower), in particular: type of ventilation (thermostated or continuously running), fan speed selection, Summer/Winter switch and room temperature thermostat.
The controller is provided with terminals for the connection of other options:
economy function (set-point variation of 6 °C), external centralized Summer/Winter changeover, window contact, minimum water temperature thermostat (TM) and cooling «EVC» and/or heating «EVH» on/off valves.
FEATURES
• Selector for the ventilation(THERMOSTATED – OFF – CONTINUOUSLY RUNNING).
• Fan speed selector (HIGH – MED – LOW). A fourth position, with no symbol on it, allows only to reset the filter alarm. In no other situation the selector must stay in this position.
• Room temperature knob (8÷30 °C). The «Comfort zone» is duly highlighted (about 20÷25 °C).
• Plastic pins for limiting the temperature range.
• Antifrost function.
• LED signal for the operating mode.
• LED signal for incorrect operation.

Remote microprocessor control suitable for the complete control of a unit (fancoil, cassette or sucted unit), in particular: type of ventilation (thermostated or continuously running), fan speed selection, Summer/Winter switch and room temperature thermostat. The controller is provided with terminals for the connection of other options: economy function (set-point variation of 6 °C), external centralized Summer/Winter changeover, window contact, minimum water temperature thermostat (TM) and cooling«EVC» and/or heating «EVH» modulating valves. Selector for the ventilation (THERMOSTATED – OFF – CONTINUOUSLY RUNNING). • Fan speed selector (HIGH – MED – LOW). A fourth position, with no symbol on it, allows only to reset the filter alarm. In no other situation the selector must stay in this position. • Room temperature knob (8÷30 °C). The «Comfort zone» is duly highlighted (about 20÷25 °C). • Plastic pins for limiting the temperature range. • Antifrost function. • LED signal for the operating mode.

Remote microprocessor control suitable for the complete control of a unit (fancoil, cassette, blower), in particular: type of ventilation (thermostated or continuously running), fan speed selection, Summer/Winter switch and room temperature thermostat.
The controller is provided with terminals for the connection of other options: economy function (set-point variationof 6 °C), external centralized Summer/Winter change over, window contact, minimum water temperature thermostat (TM) and cooling «EVC» and/or heating «EVH» on/off valves.
FEATURES
• Selector for the ventilation (THERMOSTATED - OFF - CONTINUOUSLY RUNNING)
• Fan speed selector (AUTO – HIGH – MED – LOW).
• Room temperature knob (8÷30 °C). The «Comfort zone» is duly highlighted (about 20÷25 °C).
• Plastic pins for limiting the temperature range.
• LED signal for the operating mode.
• LED signal for incorrect operation.

Remote microprocessor control suitable for the complete control of a unit (fancoil, cassette, blower), in particular: type of ventilation (thermostated or continuously running), fan speed selection, Summer/Winter switch and room temperature thermostat.
The controller is provided with terminals for the connection of other options: economy function (set-point variation of 6 °C), external centralized Summer/Winter changeover, window contact, minimum water temperature thermostat (TM) and cooling «EVC» and/or heating «EVH» on/off valves.
Power supply 230V

Remote microprocessor control suitable for the complete control of a unit (fancoil, cassette, blower), in particular: type of ventilation (thermostated or continuously running), fan speed selection, Summer/Winter switch and room temperature thermostat.
The controller is provided with terminals for the connection of other options: economy function (set-point variation of 6 °C), external centralized Summer/Winter changeover, window contact, minimum water temperature thermostat (TM) and cooling «EVC» and/or heating «EVH» on/off valves.
Power supply 24V
request
informations
Fill in the following form with your request.
We will get back to you as soon as possible.